Page view 28
e. Apply gasket sealant (Loctite No. 510) to edge of lower housing, place upper housing in place and re-install
socket screws and caps in lower housing.
C. ON-OFF POWER SWITCH (2675-0015) To replace the ON-OFF power switch:
Remove the upper housing assembly.
Remove wiring from switch.
Remove 4 bolts that hold switch to lower housing.
•Drop switch down through opening and remove the switch boot (3675-0050).
S6151-DL-MMM-010