10. Putoncutresistantgloves.Pre-scrapefoodfromslicer.
11. Usingfreshdetergentsolution,cleanthefrontsideoftheknifewithanon-abrasivepad,nylonbrush,
and/orclothwipes.Alwayswipefromthecenteroftheknifetotheouteredge.
12. Cleanthebacksideoftheknifewiththefreshdetergentsolution,non-abrasivepad,nylonbrush,and/or
clothwipes.
13. Foldaclothwipethathasbeensubmergedinfreshdetergentsolutionandworkitbetweenthering
guardandknife,startingatthebaseoftheringguard.Carefullyworktheclotharoundtheknife,
cleaningtheedgeoftheknife,edgeoftheringguardandedgeofthegaugeplate.Use extreme cau-
tion.
14. Cleantherestoftheslicerbaseandothercomponentswiththefreshdetergentsolutionandanon-
abrasivepad.
15. Liftupthefrontoftheslicerabout6inches.Aspringloadedkickstandwilldropdowntothetable
surfaceandholdthefrontoftheslicerup.Thiswillallowyoutopre-scrapefoodandcleanthetable
surfaceundertheslicerwithfreshdetergentsolution.
16. Usingafreshclothwipe,rinseslicerandareaunderslicerwithfreshhotpotablewater.
17. Sprayslicerandareaunderslicerwithfreshsanitizersolutionfromasanitizerspraybottleandallowto
airdry.Removecut-resistantgloves.
18. Oncethetablesurfaceundertheslicerhasbeenwashed,rinsedandsanitized,liftthefrontedgeofthe
slicerandpushthekickstandbackundertheslicer.Slowlylowertheslicerbacktothetable.
19. Slidethepusherarmontothesliderodandreassemblethepushertothepusherarmusingthered
handle.Reassemblethesliderodtotheproducttable.Reinstallthecenterplateandtheproducttableto
theslicer.Afterassembly,spraywithsanitizersolutionandallowtoairdry.
20. Pluginslicer.Placesharpenerinproperstoragelocation.
Gasket Inspection:
Therecommendedintervalbetweeninspectionsshallnotexceedsixmonths.
Theinspectionmustbemadebythemanufactureoranauthorizedserviceagent.
WARNING
Theslicermustberemovedfromserviceuntilrepairedbythemanufactureoranauthorizedservice
agentifanygasketorsealisfoundtobedamagedormissing.